What was found
INBOUND CREW WROTE LEFT AFT OVERWING EMERGENCY EXIT SIGN LIGHT OUT. SET EMERGENCY EXIT LIGHTS TO ARM TO CHARGE BATTERIES FOR 20 MINUTES. LIGHT NOW CHECKS OK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INBOUND CREW WROTE LEFT AFT OVERWING EMERGENCY EXIT SIGN LIGHT OUT. SET EMERGENCY EXIT LIGHTS TO ARM TO CHARGE BATTERIES FOR 20 MINUTES. LIGHT NOW CHECKS OK.