What was found
FUSELAGE EXTERIOR, STA 256 BETWEEN L22L AND L23L FORMER HAS .2500" HOLE. CUT OUT DAMAGE AREA 4.5 IN BY 1.5 IN FABRICATED & INSTALLED REPAIR ANGLE IAW SRM 53-03, FIG 7, P109 485797 G, FUNK 116102 07JAN11. REQUIRED INSP COMPLETED Q912.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FUSELAGE EXTERIOR, STA 256 BETWEEN L22L AND L23L FORMER HAS .2500" HOLE. CUT OUT DAMAGE AREA 4.5 IN BY 1.5 IN FABRICATED & INSTALLED REPAIR ANGLE IAW SRM 53-03, FIG 7, P109 485797 G, FUNK 116102 07JAN11. REQUIRED INSP COMPLETED Q912.