What was found
FWD CARGO DOOR CUTOUT WEB ON FLOOR STRUCTURE HAS CORROSION. FOUND WEB TO BE OUT OF LIMITS. R & R DOOR CUTOUT WEB. INSTALLED NEW WEB AND 2EA FWD AND 2EA AFT WEB STRAPS IAW SRM 51-10-4, 51-30-2, 51-30-5 P13 CORRECTED, REQUIRED INSP COMPLETED.