What was found
CABIN STA 237, RBL 55, BENEATH CUSP WEB CRACKED DOUBLER AT FASTENER HOLE. REMOVED 1EA FRAME FITTING IAW SRM 51-30-5. REMOVED FASTENERS & REPAIR IAW SRM 51-30-5. CUT-OUT DAMAGED AREA IAW SRM 53-10-16-801-663A-A, NDT VERIFIED DAMAGE. REMOVED IAW NDT SPM 01-10-01. FABRICATEDED FILLER DOUBLER IAW SRM 53-12-2, FIG 4 & DC9-A-53-1016-801-663A-A. TREATED AND PRIMED IAW SRM 51-10-3. INSTALLED IAW SRM 51-30-5. INSTALLED FRAME FITTING IAW SRM 51-30-1 11. REQUIRED INSP COMPLETED.