What was found
LIGHTNING STRIKE AT STA 56 AND 27 INCHES BELOW L 18 C/W SRM 53-04, FIG 38, SHEET 3 CON 3. C/W HFEC NO CRACKS NOTED. CUTOUT DAMAGE IAW SRM 53-01, FIG 4, SH4. FABED & INSTALLED DOUBLER WET WITH PRC IAW SRM. SEALED EDGES OF REPAIR AND PAINTED. JOB COMPLETE, ACFT OK FOR SERVICE RII COMPLETED ON LP 0302771, QC 1987.