What was found
FLOOR PANEL NR 68, 1 EA CRACK ON FASTENER HOLE. REMOVED CRACK IAW SRM 53-01, FIGURE 2. FABRICATED DOUBLER AND FILLER IAW SRM 53-01, FIG 2. INSTALLED DOUBLER AND FILLER IAW SRM 51-30-2. REQUIRED INSP COMPLETED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR PANEL NR 68, 1 EA CRACK ON FASTENER HOLE. REMOVED CRACK IAW SRM 53-01, FIGURE 2. FABRICATED DOUBLER AND FILLER IAW SRM 53-01, FIG 2. INSTALLED DOUBLER AND FILLER IAW SRM 51-30-2. REQUIRED INSP COMPLETED.