What was found
FUSELAGE STA 524, RBL 6", S-46R SKIN PROTRUDED. CHECKED LIMITS IAW SRM 53-00-01, P102, FIG 101. THE DAMAGE IS WITHOUT LIMIT. REPAIRED THE PROTRUDE IAW SRM 53-00-01, FIG 201, P204. REPAIR 6, WIDTH 0.98", DEPTH 0.12". REQUIRES REPEAT INSPECTIONS. EXTERNAL HFEC AT 6,000 FLT CYCLES. EXTERNAL DETAIL INSP AT 1,000 FLT CYCLES, TO BEGIN AFTER 15,000 FLT CYCLES, RII COMPLETED.