What was found
MAIN PASSENGER CABIN FWD OF STA 1100, LBL 55 FIBERGLASS FLOOR SUPPORT BROKEN OUT AT FASTENER HOLE. REMOVED FLOOR SUPPORT STA 1100, LBL 55 IAW SRM 51-30-2. RECEIVED & FABRICATED NEW FLOOR SUPPORT IAW SRM 51-10-2. RECIEVED & FABRICATED NEW BRACKET. FABRICATED, DRILLED, & LOCATED IAW SRM 51-10-2 & 51-10-4. INSTALLED IAW SRM 51-30-5.