What was found
RT ENGINE PYLON ELECTRICAL COMPARTMENT UPPER FWD STIFFENER CRACKED ON INBD END APPROX .5 INCH. REMOVED CRACKED STIFFENER IAW SRM 51-30-2. RECEIVED MATERIAL TO FABRICATE NEW STIFFENER IAW SRM 54-10-0, SHT 1, 51-10-2. LOCATED, DRILLED, D-BURRED IAW SRM 51-10-4. TREATED & PRIMED IAW SRM 51-10-3. INSTALL NEW STIFFENER IAW SRM 51-30-2. REQUIRED INSPECTION COMPLETED.