What was found
LIGHTNING STRIKE ON LT WINDOW BELT LOWER AFT/FWD CORNERS BTW STA 1060 AND 1079,1079 AND 1098,1231 AND 1250 FS. LIGHTNING STRIKES WERE BLEND IAW SRM 53-05, FIG 111. EDDY CURRENT INSP ACCOMPLISHED, NO CRACKS FOUND. AREAS TREATED IAW SRM 51-10-3 AND ERA 486640-14 REV, ORIG STA Y 1060-1079,1079-1098 AND ERA 488777-14 REV ORIG ON STA 1231-1250.