What was found
MAIN PASSENGER CABIN STA 617, BL-0 TO LBL-22 FLOOR PANEL SUPPORT IS CRACKED. REMOVED FLOOR SUPPORT & ANGLE ATTACHED. FOUND ANGLE OUT OF LIMITS IAW SRM 51-30-2 & 53-01, FIG 1. RECEIVED NEW ANGLE AND MAT FOR NEW FLOOR SUPPORT. FABRICATED, DRILLED, DEBURRED AND TRIMMED TO FIT NEW ANGLE & FLOOR SUPPORT IAW 53-13-12 51-10-2, 51-10-4 INSTALLED IAW SRM 51-30-2.