What was found
MAIN CABIN STA 541 RT CUSP WEB HAS HOLE. REMOVED .5" DAMAGE, FABRICATED REPAIR PART. HFEC AREA FOUND CRACK FREE CONDITION IAW NDT SPM 06-10-01 INSTALLED AND PRIMED, WORK ACCOMPLISHED IAW SRM 51-13-2, FIG 4, 51-10-4, 51-10-3, DWG SG09530019. REQUIRED INSPECTION COMPLETED.