What was found
DURING PERFORM OPEN HOLE HFEC INSP CRACK WAS FOUND IN 1 OF THE HOLES ON NS2598 BULKHEAD THE SAME 5312-01144-FOR PERFORM J/C 5312-01144-04B FOUND CRACK IN ONE OF THE HOLE OF BS2598 BULKHEAD IAW SRM 53-80-08, REPAIR 11 ER/A488618-14, REV 2 IAW FORM REPAIR. IAW SRM53-80-08, REPAIR 11, REQUIRE REPEAT INSPECTION: OPEN HOLE AND EDDY CURRENT INSP THRESHOLD 6000 CYCLES AFTER REPAIR INSTALLATION. INSPECTION INTERVAL 1500 CYCLES.