What was found
DURING PERFORM OPEN HOLE HFEC INSPECTION, CRACK WAS FOUND IN 1 OF THE HOLE ON BS 2598 BULKHEAD REPAIRED ER/A488618-14, REV1. ER/A488618-14, REV 2 PERFORMED REPAIR IAW SRM53-80-08, REPAIR 11. OPEN HOLE AND SURFACE EDDY CURRENT. INSP THRESHOLD, 6000 CYCLES AFTER REPAIR INSTALLATION. INSPECTION INTERNAL 1500 CYCLES.