What was found
RT WING T/E FIXED PANEL INBD OF AILERON IS DELAMINATED. APPROX 36 SQ INCHES. R & R PANEL IAW SRM 51-30-01 AND 51-30-2. REPAIRED UPPER T/E SPAR IAW ERA 488339-147. REQUIRED INSP COMPLETED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RT WING T/E FIXED PANEL INBD OF AILERON IS DELAMINATED. APPROX 36 SQ INCHES. R & R PANEL IAW SRM 51-30-01 AND 51-30-2. REPAIRED UPPER T/E SPAR IAW ERA 488339-147. REQUIRED INSP COMPLETED.