What was found
MAIN CABIN STA 200 TO 218, RBL 19 FLOOR SUPPORT HAS CORROSION. REMOVED CORROSION IAW SRM 51-10-03. ORIGINAL .094 REMOVED .022 REMAIN .072 FOUND TO BE OUT OF LIMITS IAW SRM 53-01, FIG 1. REMOVED SUPPORT IAW SRM 51-30-01. LOCATED, FABRICATED AND DRILLED NEW SUPPORT IAW SRM 51-10-04. INSTALLED IAW SRM 51-30-01. REQUIRED INSP COMPLETED.