What was found
MAIN CABIN STA 200, LBL 1 TO 20 FLOOR SUPPORT HAS CORROSION. REMOVED CORROSION ORIGINAL MAT .060 REMOVED .048, REMAINING .012 FOUND TO BE OUT OF LIMITS. REMOVED FLOOR SUPPORT TRIMMED, LOCATED , DRILLED, TREATED, PRIMED, SEALED AND INSTALLED NEW FLOOR SUPPORT ALL WORK ACCOMPLISHED IAW SRM'S 53-13-1, FIG 11, 51-10-1, FIG 53-01, FIG 1, 51-10-2, 51-10-4, 51-10-3, 51-20-00, 51-30-5.