What was found
MAIN PASSENGER CABIN BETWEEN STA 1116-1136, BL 0, FLOOR SUPPORT CORRODED. REMOVED CORROSION WAS .056 REMAIN MAT .02 REMOVED .032 MATERIAL FOUND OUT OF LIMITS. CUT OUT 20 IN OF FLOOR SUPPORT. RECEIVED FLOOR SUPPORT REPAIR ASSY. FABRICATED REPAIR ASSY. INSTALLED IAW DC9-53-10-03-801-663AM, 53-01, 51-10-1 P-180.