What was found
MAIN CABIN METAL FLOOR PANEL 60B HAS ELONGATED HOLES AND 2EAHAT CHANNELS CHAFED. BLENDED HAT CHANNELS OUT OF LIMITS IAW SRM 53-01 FIG 1. FABRICATED 2EA HAT CHANNEL SPLICES. CUT AND TRIMMED 2EA HAT CHANNELS. INSTALLED 2EA HAT CHANNELS AND SPLICES IAW SRM 51-30-2, 51-30-8. CUTOUT DAMAGED AREA IAW 53-05 FABRICATED NEW DOUBLER AND FILLER IAW SRM 53-05 FIG 1. INSTALLED FILLER AND DOUBLER IAW SRM 53-05 FIG 1 P239.