What was found
FLOOR BOARD SUPPORT HAS CORROSION, AT STA 200 FROM CENTERLINE TO 20 INCHES RIGHT. REMOVED CORROSION IAW DC9 SRM 51-10-3, PARA 26, FOUND OUT OF LIMITS IAW DC9 SRM 53-01, FIG 1, SHT 3. FABRICATED, LOCATED, DRILLED AND INSTALLED FLOOR BOARD SUPPORT AT STA 200, BL0 TO RBL 20 IAW DC9 SRM 53-13-1, FIG 11, ITEM 11, SRM 51-40-04, PARA C, AND SRM 51-30-5, PARA7.