What was found
FOUND WEAR BETWEEN STA 2300-2320 WITH GOUGE AT 2313. BLENDED AREA STA 2300-2320 EXCEPT STA 2313. MAX MATERIAL REMOVED IS .007 INCH HFEC NO CRACKS. WITHIN LIMITS PER SRM 53-00-01 FIG 101. TREATED, PRIMED APPLIED TEFLON COATING PER AA 5331-01190-02. ERA 489979-14AD DOCUMENTS REWORKED AREA STA 2313 DRILLED OUT GOUGE TO .190 INCH AND INSTALLED BLIND FASTENER PER SRM 53-00-01 FIG 201. REQUIRES REP INSPECTION AT 1000 FC INTERVALS. REQUIRES PERMANENT REPAIR WITH SOLID FASTENER AT 6000 FC. REQUIRED INSPECTION COMPLETED.