What was found
FUSELAGE EXTERIOR AT CANTED FRAME STA 1292 BETWEEN L14L AND L15L SKIN CRACKED. REMOVED EXISTING DOUBLER IAW SRM 51-30-2. REMOVED CRACKED SKIN BY EXTENDING EXISTING CUT OUT IAW SRM 53-04 FIG 12B. HFEC INSPECTION IAW NDTSPM 06-10-01. NO CRACK INDICATIONS. FABRICATED NEW DOUBLER INSTALLED REPAIR IAW SRM53-04 FIG 12B. REPETITIVE INSPECTED EVERY 6000 LANDINGS PER SRM 53-04 FIG 12B P102 18 FEB 11 REQUIRED INSPECTION COMPLETED Q968/280012 17 FEB 11.