Service difficulty report · Floor Support · Doug DC951

Difficulty date
February 25, 2011
Submitted
February 28, 2011
Operation
Air carrier
Aircraft
N787NC
Make and model
Doug DC951
Aircraft serial
48149
Aircraft time
67,736 hours, 61,525 cycles
Part
Floor Support
Condition
Corroded
Location
Fuselage
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FORWARD WET AREA STA. 200 LBL 22-44 FLOOR SUPPORT HAS CORROSION. REMOVED CORROSION AT FLOOR SUPPORT STA 200 LBL 22-44 IAW DC9 SRM 51-10-3. ORIG MAT .060 IAW DC9 SRM 53-13-1FIG 11. REMOVED .020 REMAINING .040 OUT OF LIMITS IAW DC9 SRM 53-01. REMOVED FLOOR SUPPORT IAW DC9 SRM 51-30-2. FABRICATED NEW FLOOR SUPPORT TREATED AND PRIMED. INSTALLED FLOOR SUPPORT IAW DC9 SRM 51-30-2.