As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FORWARD WET AREA STA 160-200 RBL 44 FLOOR SUPPORT HAS CORROSION. REMOVED CORROSION FROM AREA IAW SRM 51-10-3, MATL THICKNESS IS .060 IAW 53-13-1 REMAINING IS .040 FOUND TO BE OUT OF LIMITS IAW SRM 53-01 FIG 1 MATERIAL ID EXTRUSION NR 265479 RECEIVED MATERIAL PO NR 1021992 IAW SRM 53-13-1. FABRICATED LOCATED DRILLED IAW SRM 51-10-4. TREATED AND PRIMED IAW SRM 51-10-3. INSTALLED IAW SRM 51-30-5.