Service difficulty report · Floor Support · Doug DC951

Difficulty date
February 28, 2011
Submitted
March 1, 2011
Operation
Air carrier
Aircraft
N787NC
Make and model
Doug DC951
Aircraft serial
48149
Aircraft time
67,736 hours, 61,525 cycles
Part
Floor Support
Condition
Corroded
Location
Bs 160-200 Rbl44
Stage of operation
IN
How discovered
9
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FORWARD WET AREA STA 160-200 RBL 44 FLOOR SUPPORT HAS CORROSION. REMOVED CORROSION FROM AREA IAW SRM 51-10-3, MATL THICKNESS IS .060 IAW 53-13-1 REMAINING IS .040 FOUND TO BE OUT OF LIMITS IAW SRM 53-01 FIG 1 MATERIAL ID EXTRUSION NR 265479 RECEIVED MATERIAL PO NR 1021992 IAW SRM 53-13-1. FABRICATED LOCATED DRILLED IAW SRM 51-10-4. TREATED AND PRIMED IAW SRM 51-10-3. INSTALLED IAW SRM 51-30-5.