What was found
MAIN CABIN FLOOR INTERCOSTAL WEB CRACKED AND UPPER TEE CHORD CRACKED AT STA 674, BL-0 RBL 082. REMOVED CRACKED TEE CHORD FROM STA 570 TO 674, BL-0 AT MAIN CABIN FLOOR IAW SRM 51-30-02, PG 29. INTERCOSTAL EVALUATED BY NDT-NO CRACKS FOUND. FABRICATED TEE CHORD AND REPAIR ANGLES IAW SRM 51-70-5, PG 16-26. INSTALLED CHORD AND REPAIR ANGLES IAW SRM 51-30-02 PGS 1-5, AMD FIG 3, PG 16, SRM 51-70-5.