What was found
CRACK ON SUPPORT ANGLE AT PYLON 2 WEB BEHIND PNEUMATIC DUCTS /FIRE SHIELD ACCESS THRU DOOR 8206A. DRILLED .025 STOP HOLE AT END OF THE CRACK IAW DC-9 SRM 54-01 FIG 2 SHT 3 HFEC INSPECTION STOP DRILL AND NO PROG NOTED FABBED NEW REPAIR ANGLES 2 EA. HFEC SURFACE OF 2 ANGLES PER NDT SPM 06-10-01.001 NO CRACKS DETECTED. TREATED AND PRIMED 2 REPAIR DOUBLER ANGLES IAW DC-9 SRM 51-10-3 PARA 14, 21 INST IAW DC-9 SRM 54-01 FIG 2 SHT 3.