What was found
MAIN CABIN METAL SKIN FLOOR PANEL NR 73 HAS 1EA PUNCTURED HOLE. CUTOUT PUNCTURED AREA (2.0625" X 1.0625") IAW SRM 53-01, FIG 4 HFEC VERIFIED DAMAGE. REMOVED IAW NDT SPM 06-10-01.001 ORIG MAT .020, 7075T6 IAW SRM 53-23- FIG 5 FABRICATED & LOCATED & DRILLED IAW SRM 53-01, FIG 4 AND 51-10-4. TREATED & PRIMED IAW SRM 51-10-3 INSTALLED IAW SRM 53-01, FIG 4 AND SRM 51-30-2. REQUIRED INSP COMPLETED.