What was found
UPON REMOVAL OF FLOOR SUPPORT FOUND A DOUBLE DRILLED HOLE IN FLOOR BEAM AT STA 636, LBL-7, CORRECTED. REMOVED DOUBLER, DRILLED HOLE BY CUTOUT STA 636, LBL-7. FABRICATED ANGLE FROM AND FILLER FROM IAW SRM 53-05, FIG 79A LOCATED AND DRILLED IAW SRM 51-10-4. TREATED AND PRIMED IAW SRM 51-10-3 INSTALLED IAW SRM 53-05, FIG 79A. P180 REQUIRED INSP, COMPLETED.