What was found
FUSELAGE SKIN CORROSION AT STA 1116, STR 28L, FOUND DURING MAUS SCAN INSP. AREA FOUND TO BE OUT OF LIMITS IAW SRM 53-04, PG 218, FIG 38. CUT OUT DAMAGE AREA IAW SRM 53-04 PG. FABRICATED REPAIR PARTS IAW SRM 53-04 TREATED AND PRIMED REPAIR PARTS IAW SRM 51-10-3, PG 5. INSTALLED CONICAL WASHER ON EXISTING COUNTERSINKS ON THE AREA IAW SRM 53-04. INSTALLED REPAIR PARTS ON THE AREA IAW SRM 53-04.