What was found
AFT ACC COMPT INTERCOSTAL BETWEEN STA 1314-1326 ABOVE EXTERIOR PULL HANDLE BOX BENT. RECEIVED INTERCOSTAL AND CLIPS IAW SRM 51-30-2. CLIPS CRACKED AND INTERCOSTAL NOTED TO HAVE GOUGE & TOOLING MARKS OUT OF LIMITS IAW SRM 53-01, FIG1. T=.032 2024T3 FOR CLIPS .025 2024T3 FOR INTERCOSTAL. RECEIVED MATERIAL. FABRICATED & INSTALLED 2 CLIPS & INTERCOSTAL IAW SRM 51-10-2, 51-10-4, 53-13-4, FIG 3 & DWG 9917701, 51-30-2, 51-30-5.