What was found
MAIN CABIN STA 160 TO 218, BL 0, FLOOR SUPPORT HAS CORROSION. REMOVED CORROSION IAW SRM 51-10-3. ORIGINAL THICKNESS WAS .060 IAW SRM 53-13-1, FIG 11. AFTER BLEND THICKNESS IS OVER 50 PERCENT LOSS OUT OF LIMITS IAW SRM 53-01. REMOVED SUPPORT IAW SRM 51-30-5. FABRICATED NEW SUPPORT IAW SRM 53-13-1 FIG.11. INSTALLED NEW SUPPORT IAW SRM 51-30-5. REQUIRED INSP COMPLETED.