What was found
MAIN CABIN STA 734, LBL-50 LT SIDE CUSP WEB CRACKED APPROX 1 IN. STOP DRILLED CRACK IAW SRM 53-10-16. REMOVED 1 FASTENER IAW 51-30-2. REQUESTED NDT, NDT REPORTS CRACK CONTAINED. RECEIVED LOCATED, DRILLED, FIT, TRIMMED, AND DEBURRED REPAIR DOUBLER IAW SRM 51-30-4. TREATED AND PRIMED DOUBLER IAW SRM 51-10-3. INSTALLED DOUBLER IAW SRM 51-30-2. REQUIRED INSP COMPLETED.