What was found
MAIN CABIN METAL CABIN FLOOR PANEL NR 61, 1 EA HAT CHANNEL CRACKED ON END. CUT OUT CRACKED AREA OF HAT CHANNEL PER DC 9 SRM 53-05 FIG 1. HFEC CHECK COMPLETED DAMAGE REMOVED PER NDT SPM 06-10-01. FABBED LOCATED, DRILLED TREATED & PRIMED NEW HAT SECTION AND SPLICE PER DC 9 SRM 51-10-2, 51-10-4, 51-10-3, AND 53-05 FIG 1. REPAIR WEIGHT 22G PER SCALE H9573 INSTALLED REPAIR & REPAIR TAG PER DC9 SRM 53-05 FIG 1 & 51-30-2 AND DPS 900-5-1.