As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
MAIN CABIN FLOOR PANEL 70 HAS 1 EA HOLE CRACKED AND ELONGATED. REMOVED DAMAGED AREA IAW DC9 SRM 53-05 FIG 1. HFEC INSP IAW DC9 NDT SPM 06-10-01. FOUND DAMAGE TO BE REMOVED. REPAIRED FLOOR PANEL IAW DC9 SRM 53-05 FIG 1. INSTALLED ID TAG PER DPS 900-5-1. REQUIRED INSPECTION COMPLETED.