What was found
MAIN CABIN JUST UNDER FLOOR STA 775 RBL-44 VERTICAL SUPPORT CRACKED APPROX 2 INCHES. REMOVED CRACKED SUPPORT, RECEIVED NEW SUPPORT. LOCATED, DRILL, DEBURRED, TREAT, PRIME & INSTALL IAW DC-9 SRM 51-30-2, 51-30-5, 51-10-4, 51-10-3. REQUIRED INSPECTION COMPLETED.