What was found
MAIN CABIN STA 617 BETWEEN BL-0 AND LBL-22 FLOOR SUPPORT CHAFED. BLENDED AREA IAW DC9 SRM 53-13-2 FIG 4 AND 51-10-3. ORIG THICKNESS WAS .050 IAW DC9 SRM 53-13-2 FIG4, AFTER BLEND THICKNESS IS .027, OUT OF LIMITS IAW DC9 SRM 53-01. REMOVED AND FABRICATED NEW SUPPORT IAW DC9 SRM 53-13-2 FIG 4. INST NEW SUPPORT IAW DC9 SRM 51-30-2.