What was found
MAIN CABIN FLOOR PANEL 65 HAS 4 EA FASTENER HOLES CRACKED. REMOVED DAMAGE BY CUTOUT 2.25" X 21"-ORIGINAL MAT. 7075T-6.025 IAW DC-9 SRM 53-01 FIG 4-NDT VERIFIED DAMAGE. REMOVED IAW NDT SPM 06-10-01 RECEIVED MAT 7075-T6-.025. FABBED LOCATED, TRIMMED, DRILLED, COUNTERSUNK, DEBURRED, TREATED, PRIMED & INSTALLED REPAIR DOUBLER & FILLER IAW DC-9 SRM 53-01 FIG 4 SH 4, 53-30-2 REQUIRED INSPECTION COMPLETED 09 MAR 11.