What was found
FLOOR SUPPORT FOR MAIN CABIN WORN AT FLOOR PANEL CONTACT POINT RT SIDE AT STA 408 & 427. REMOVED FLOOR SUPPORT MAIN CABIN RT STA 389 TO 465 IAW DC9-A-53 -20-01-201-925A-A. REMOVED DAMAGE STA 408 & 427 IAW DC9 SRM 53-05, FIG 20A OUT LIMITS - FABRICATED (2EA) ANGLE REPAIR, (2EA) WEAR STRIP & (1EA) SHIM, IAW DC9 SRM 53-05, PG 100, FIG 20A.