As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT CABIN FLOOR SUPPORT -Y254 HAS 2 INCH AREA OF EXFOLIATION IN AND AROUND GALLEY MOUNT HOLE FWD OF FR70 BLENDED CORROSION IAW SRM 51-74-00 ORIG MAT=.071" L=1.8" W=1.3" D=.038 FOUND OUT OF LIMITS IAW SRM 53-00-14 REMOVED FLOOR SUPPORT -Y254 FROM FR68 TO FR70 IAW SRM 51-42-11 INSTALLED NEW FLOOR SUPPORT FROM FR68 TO FR70 AT -Y254 IAW SRM 51-42-11.