As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CABIN FLOOR SUPPORT Y+765 HAS 6" X 3" AREA OF EXFOLIATION ABOVE FR 66. BLENDED AREA IAW SRM 51-74-00 L=4" W=2.9" D=0.087" FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15. REMOVED FLOOR SUPPORT IAW SRM 51-42-11. RECEIVED NEW PART RAIL SEAT TRACK. LOCATED & DRILLED IAW SRM 51-44-11. INSTALLED IAW SRM 51-42-11. APPLIED TOP COAT IAW SRM 51-75-12.