What was found
AFT CABIN FLOOR SUPPORT Y+765 HAS 10 INCH LONG AREA OF SCRIBE DAMAGE WITH EXFOLIATION BETWEEN FR 66 AND FR 67. BLENDED AREA IAW SRM 51-74-00 L=6.4"W=1.5" D=0.065 FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15. REMOVED FLOORBEAM IAW SRM 51-42 -11. RECEIVED NEW FLOORBEAM, RAIL SEAT TRACK LOCATED AND DRILLED NEW FLOORBEAM IAW SRM 51-44-11. INSTALLED FLOORBEAM IAW SRM 51-42-11. APPLIED TOP COAT IAW SRM 51-75-12.