What was found
AFT CABIN FLOOR SUPPORT Y+765 HAS 2 INCH AREA OF EXFOLIATION AROUND AND IN GALLEY MOUNT HOLE FWD OF FR 70. BLENDED AREA IAW SRM 51-74-00 L=2.25" W=1.5" D=0.080 FOUND TO BE OUT OF LIMITS IAW TRM 53-41-15. REMOVED FLOOR SUPPORT IAW SRM 51-42-11. DRILLED AND LOCATED NEW FLOOR SUPPORT BEAM TREATED AND PRIMED NEW HOLES IAW SRM 51-21-11. INSTALLED FLOOR BEAM IAW SRM 51-42-11. INSTALLED HARD POINT FITTINGS IAW SRM 51-42-11. APPLIED TOP COAT IAW SRM 51-75-12.