What was found
AT FRAME 12-24 Y254 FLOORBOARD SUPPORT CORRODED. BLENDED AREA IAW SRM 51-74-00 L=3.10" W=1.70 D=.049" FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14 FIG 105. REMOVED FLOORBEAM IAW 51-42-11. LOCATED AND DRILLED NEW BEAM IAW SRM 51-44-11. INSTALLED NEW BEAM IAW SRM 51-42-11.