Service difficulty report · Floor Support · Airbus A319114

Difficulty date
March 15, 2011
Submitted
March 16, 2011
Operation
Air carrier
Aircraft
N314NB
Make and model
Airbus A319114
Aircraft serial
1191
Aircraft time
30,716 hours, 15,721 cycles
Part
Floor Support
Condition
Corroded
Location
Fuselage
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AFT CABIN Y+1292 HAS 6"X3" AREA OF EXFOLIATION ABOVE FR66 ON FLOOR SUPPORT. FOUND SEVERAL AREAS ON AFT END OUT OF LIMITS. DIMENSIONS ARE L=6.0", W=2.5", D=0.082" OUT OF LIMITS IAW TRM 53-41-15. ORIG MATERIAL 0.155". REPLACED FLOOR SUPPORT Y+1292 FROM FR64 TO FR66 IAW SRM 51-42-11.