As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FRAME 20 Y-1292 FLOORBOARD SUPPORT CORRODED BLENDED AREA IAW SRM 51-14-00 CHECK LIMITS L=1.10" W=1.00"D=0.35 FOUND TO BE OUT OF LIMITS IAW SRM 53-11-14 FIG 105 REMOVED AND REPLACED W/NEW FLOORBEAM SUPPORT P/N D5311281400200, FR12 Y-1292 FR24 IAW SRM 51-42-11.