What was found
AFT CARGO COMPT RT SIDE FLOOR SUPPORT HAS 1 EA FASTENER HOLE ON RADIUS AND SOME FASTENERS HOLES HAVE NO E.D. BETWEEN HOLES AT FRAME BS 1136.091. REMOVED CORR FROM INTERCOSTAL ORIG MAT, 040 REMOVED.002 REMAIN .038 FOUND TO BE IN LIMITS IAW DC9 SRM 53-01 FIG 1 SHT 3. RE-INSTALLED FLOOR SUPPORT, SPLICES, TIE DOWN TRACK, 4 EA NUT PLATES IAW DC-9 SRM 51-30-1, 51-10-3, 53-01 FIG 1 SHT 3, 51-30-2, 51-30-5.