As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOOR SUPPORT AT BL 0 BETWEEN STN 1640 AND STN 1661 CORRODED AS MARKED. REMOVED CORR IAW SRM 51-10-02. ORIGINAL MAT THICKNESS=.050" OUT OF LIMITS IAW SRM 53-00-51. REMOVED FLOOR SUPPORT AND STIFFENER IAW SRM 51-40-02. FABBED NEW CHANNEL SUPPORT IAW DWG 146N5242 AND AMS 2770. LOCATED AND DRILLED NEW CHANNEL SUPPORT IAW SRM 51-40-05. INSTALLED NEW CHANNEL SUPPORT SUPPORT AND STIFFENER IAW SRM 51-40-02.