What was found
MAIN CABIN STA 785 RBL 50 PREVIOUS REPAIR NOT MEETING FASTENER REQUIREMENT. REMOVED EXISTING REPAIR IAW SRM 51-30-2. FABBED AND INSTALLED FILLER.040" 7075-T6 AND DOUBLER .050" 7075-T6 IAW SRP DC-9 A-53-10-16-801-663A-A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN CABIN STA 785 RBL 50 PREVIOUS REPAIR NOT MEETING FASTENER REQUIREMENT. REMOVED EXISTING REPAIR IAW SRM 51-30-2. FABBED AND INSTALLED FILLER.040" 7075-T6 AND DOUBLER .050" 7075-T6 IAW SRP DC-9 A-53-10-16-801-663A-A.