What was found
FUSELAGE EXTERIOR STA 1209 BETWEEN L13L AND L12L SKIN CRACKED AT FASTENER. REMOVED FASTENER IAW SRM 51-30-02, VERIFIED CRACK IAW DC9 SRM 53-01 FIG 4. UPPER CUTOUT IS .890X 1.0", LWR CUTOUT IS .800 X 1.1", FABBED 1EA DOUBLER AND 2EA FILLERS IAW SRM 53-01 FIG 4 ORG MAT .040 2014 T6 IAW DC9 SRM 53-33-0 FIG 4 SUB .040 2014T6 .040 7075T6 IAW DC9 51-60-0 FIG 1 INSTALLED 2EA FILLERS 1EA DOUBLERS IAW DC9 SRM 53-01 FIG 4 AND DC9 SRM 51-30-02, 51-30-08.