Service difficulty report · Floor Support · Doug DC951

Difficulty date
March 24, 2011
Submitted
March 25, 2011
Operation
Air carrier
Aircraft
N779NC
Make and model
Doug DC951
Aircraft serial
48101
Aircraft time
71,333 hours, 66,584 cycles
Part
Floor Support
Condition
Corroded
Location
Fuselage
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

MAIN CABIN STA 200 RBL 47 TO 57 FLOOR SUPPORT HAS CORROSION. REMOVED FLOOR SUPPORT IAW DC-9 SRM 51-30-5. REMOVED CORROSION IAW DC-9 SRM 51-10-3. ORIG MAT .060 MAT REMOVED .050 MAT REMAIN.010. FOUND TO BE OUT OF LIMITS L=8.00 W: 1.75D= .050 IAW DC-9 SRM 53-01 FIG 1. FABBED NEW FLOOR SUPPORT S2652479 7075-T6. INSTALLED NEW SUPPORT IAW DC-9 SRM 51-30-5.